Samsung AQV12TWQNXSA 사용자 설명서

다운로드
페이지 48
Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the 
table for efficient use.
  If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
  If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of 
specified capacity according to the using conditions.
Mode
Indoor temperature
Outdoor temperature
Indoor humidity
Cooling 
16˚C~32˚C
-10˚C~46˚C
Relative humidity 80% or less
Heating
27˚C or less
-15˚C~24˚C
-
 Dry
18˚C~32˚C
-10˚C~46˚C
-
•   A Samsung-branded air conditioning unit installed in an area which is not easily accessible (including without
limitation roofs or positions above 2.4 metres for the outdoor unit) may require additional costs for labour and 
access equipment as may be mandated by occupational health and safety requirements.  Such costs are to be 
borne by you should service or maintenance (including service or maintenance covered by your warranty or by 
a consumer guarantee) be required.
Checking before use
Maintaining your air conditioner
Internal protections via the unit control system
 This internal protection operates if an internal fault occurs in the air conditioner.
Type
Description
Against cold air
The internal fan will be off to prevent cold air when the heat pump is heating.
Defrost cycle
The internal fan will be off to defrost ice when the heat pump is heating.
Vertical air flow blade will be closed during defrost cycle and it will open again during 
heating operation after defrost cycle.
Protect compressor
The air conditioner does not start operating immediately to help protect the compressor 
of the outdoor unit after it has been started.
•   If the heat pump is operating in Heat mode, defrost cycle is actuated to help remove frost from an outdoor unit that
may have deposited at low temperatures. 
The internal fan is switched off automatically and restarted only after the defrost cycle is completed.
English-9
SA_BORACAY_IB&IM_EN_DB98-34690A_del_screw.indd   9