The outdoor unit is loaded with 
 
a
 s
ti
 :
e
r
e
h
p
s
o
m
t
a
 
o
t
n
A
0
1
4
R
 t
n
e
v
 t
o
n
 
o
D
 
 .
t
n
a
r
e
g
ir
f
e
A
0
1
4
R
 
 
greenhouse gas,  covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975. 
 
It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. 
Use Vacuum Pump as seen in the picture. 
1.  Connect each assembly pipe to the appropriate valve on the outdoor unit and 
2. 
applying the following torque:
•   When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor 
 
before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works 
with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle 
abnormally high. It may cause explosion and injury.
Purging the connected pipes
Outdoor unit
Indoor unit
Gas pipe side
Liquid pipe side
•  Excessive torque can be cause of gas leakage.
•   Make the electrical connection and leave the system into “stand by 
mode”. Do not turn on the system! 
This is necessary for better vacuum operation (full OPEN position of 
Electronic Expansion Valve - EEV -).
MAX_XSA_IBIM_DB98-33747A_E.pdf
Outer Diameter
Torque
N•m
(kgf•cm)
ø6.35 mm
14 ~ 18
140 ~ 180
ø9.52 mm
34 ~ 42
350 ~ 430
ø12.70 mm
49 ~ 61
500 ~ 620
ø15.88 mm
68 ~ 82
690 ~ 830