When error occurs, take necessary measures by referring to the following table. For more information on necessary 
measures for errors, refer to the service manual.
Error indicator
Error
Measures for the installer to take
 Display
LED Display
LED 1 LED 2
LED 3
 /   / 
Communication 
error between 
indoor and outdoor 
units
•  Check the connection wire between the 
indoor and outdoor units (whether the 
power cable or communication cable is 
crossed or not).
Error on indoor 
temperature sensor
•  Check the connection of the connector.
Error on indoor 
heat exchanger
•  Check the connection of the connector.
Error on indoor fan 
motor
•  Check the connection of the connector.
•  Remove foreign substance. (Check for the 
cause that restrains motor.)
 display and 
all LEDs blink.
EEPROM/Option 
error
•  Re-set options.
Refrigerant flow 
blocking error
•  Check if the stop valve is completely 
open.
•  Check if there is any blockage in the 
refrigerant pipe which connects the 
indoor and outdoor units.
•  Check for refrigerant leak.
Lack of refrigerant 
(for inverter models 
only)
•  Check if a sufficient amount of refrigerant 
is additionally charged for the pipe 
longer than specified in piping codes and 
standards. 
•  Check for refrigerant leak between valve 
and pipe connection.
   This LED pattern 
appears when an 
error occurs on the 
outdoor unit. 
 
 : Off,    : Blinking,    : On