Samsung SSA-S1000 사용자 설명서

다운로드
페이지 16
8_
 
product introduction
product introduction
CABLE COLOR SCHEME
Item
Cable Color
Signal Line
Description
Power
Red
DC+12V
+12V supplied
Black
GND 
Earth-Grounding for Power
Input
Yellow
AUX INPUT#1
Select a Lock Type
Blue
Door Contact Sensor
Door Sensor Connection Port
Green
Exit Button 
Exit Button Connection Port
Output
Purple
Alarm Out 
Alarm Device Connection 
Port
White
Door Lock Out 
Door Lock device connection 
port
Not used
Gray
Orange
Brown
CABLE SELECTION
Item
Cable Type
1
Power (DC +12V)
Belden #9409, 18 AWG  2 Conductor, Unshielded
Belden #9409, 18 AWG  2 Conductor, Unshielded
2
Door Contact Sensor 
Exit Button 
Sensor Input
Belden #9512, 22 AWG  4 Conductor, Shielded
Belden #9514, 22 AWG  8 Conductor, Shielded
3
Door Lock 
Alarm Device
Belden #9409, 18AWG  2 Conductor, Unshielded