Audio Command Center Series Manual — P/N 51889:E1  6/8/2010
23
Controls and Indicators
Product Description
1.3  Controls and Indicators
1.3.1  Single Zone Operation (ACC-25/50, ACC-25/50ZS, ACC-
25/50ZST)
     
Figure 1.5 depicts Single Zone operation with the 
maximum capacity of five messages.  Single Zone 
may be configured for two to five message control 
(refer to Section 2,  ”Field Programming” on page 32).
ALL-CALL:
used to select All Call function when ACC-
25/50 Series is programmed for Single Zone 
operation.  Selecting this button also activates 
the Master Command Bus, which is used to 
trigger Distributed Audio Panels.  Single Zone 
operation directs the same message to both 
amplifier circuits (S3 DIP switches 1, 2 and 3 
set to one of the valid options other than all 
OFF)
AUDIO ON/OFF:
used to indicate that speaker circuits are activated when ACC-25/50 Series is programmed 
for Single Zone operation (S3 DIP switches 1, 2 and 3 set to one of the valid options other 
than all OFF).  
Push-button switch can be used to deactivate the audio amplifiers that were 
activated by the FACP
MESSAGE 1 - used to manually transmit Message 1 over speaker circuit
MESSAGE 2 - used to manually transmit Message 2 over speaker circuit
MESSAGE 3 - used to manually transmit Message 3 over speaker circuit
MESSAGE 4 - used to manually transmit Message 4 over speaker circuit
MESSAGE 5 - used to manually transmit Message 5 over speaker circuit
1.3.2  Dual Zone Operation (ACC-25/50 Only)
Figure 1.6 depicts Dual Zone operation which sup-
ports the generation of one message only (refer to Sec-
tion 2,  ”Field Programming” on page 32
).
ZONE 1:
used to select Zone 1 when ACC-25/50 is 
programmed for Dual Zone operation.  Dual 
Zone operation directs a single message to 
either or both amplifier circuits (S3 DIP 
switches 1, 2 and 3 set to OFF).
ZONE 2:
used to select Zone 2 when ACC-25/50 is 
programmed for Dual Zone operation (S3 DIP 
switches 1, 2 and 3 set to OFF)
Figure 1.5  Controls and Indicators
                   Single Zone Operation
acc2
5kybln
k.wmf
ALL-CALL
AUDIO ON/OFF
MESSAGE 1
MESSAGE 2
MESSAGE 3
MESSAGE 4
MESSAGE 5
POWER ON
SYSTEM 
TROUBLE
MESSAGE
TROUBLE
GENERATOR
TONE
GENERATOR
TROUBLE
RECORD
PLAYBACK
TROUBLE
SILENCE
MICROPHONE
TROUBLE
Figure 1.6  Controls and Indicators
                   Dual Zone Operation
acc25
kyblnk.
w
m
f
ZONE 1
ZONE 2
MESSAGE 1
POWER ON
SYSTEM 
TROUBLE
MESSAGE
TROUBLE
GENERATOR
TONE
GENERATOR
TROUBLE
RECORD
PLAYBACK
TROUBLE
SILENCE
MICROPHONE
TROUBLE