att door phone controller 사용자 설명서
Operation – Basic Door Answer Function
Table 4-1. AT&T Door Phone Controller Option Selection Information
Mode Option/
Listen
Listen
Options
Verify
Press
For
Press
For
Default
Delay Before
To Select Option
00
Single
000 to 255 for 0 to 255
Double
30 sec.
Door Ajar
Beep
seconds of delay after strike
Beep
Call-back
To Verify
01
plate release stops until
AT&T Door Phone Controller
calls back to indicate that
door is ajar
AT&T Door Phone Controller
calls back to indicate that
door is ajar
Ring/Chime
To Select Option
10
Single
24 (for 2 sec. on 4 sec. off
Double
2 sec./
Cadence
Beep
cadence)
o r
Beep
4 sec.
To Verify
11
15 (for 1 sec. on 5 sec. off
cadence)
Ring/Chime
To Select Option
20
Single
00 to 99 (0 to 99 second(s)
Double
30 sec.
Duration
Beep
ring/chime)
Beep
To Verify
21
Door Unlock
To Select Option
30
Single
4 digits (first digit must be
Double
6736
Code
Beep
0,3,4,5,6,7 or 8
Beep
“OPEN”
To Verify
31
remaining digits can be set
from 0 to 9)
Door Unlock
To Select Option
40
Single
00 to 99 (door lock active
Double
4 sec.
Duration
Beep
time in sec.)
Beep
To Verify
41
Enable Door
To Select Option
50
Single
1
Enable door code
Double
1
Code
Beep
0 Disable door code
Beep
(Enabled)
To Verify
51
Door Ajar
To Select Option
50
Single
2
For callback after strike
Double
2
Mode
Beep
plate release only
Beep
To Verify
51
3
For callback anytime
door is opened
door is opened
Forced
To Select Option
60
Single
010 to 255 (unit disconnects
Double
120 sec.
Disconnect
Beep
in 10 to 255 sec.)
Beep
Time-Out
To Verify
61
Reset Options
To Select Option
70
Single
## (to restore factory default
Double
N/A
to Factory
Beep
conditions)
Beep
Defaults
To Verify
71
NOTE: The Door Ajar Delay (Option Selection) will begin when the call to the door speaker is disconnected.
4-8 Installation - Dedicated Trunk Port