Intel SC5400LX 사용자 설명서

다운로드
페이지 104
Reliability, Serviceability, and Availability 
Intel® Server Chassis SC5400 5U Kit TPS
 
84  
Revision: 
1.0 
 
 
10.   Reliability, Serviceability, and Availability 
10.1  Mean Time Between Failure 
The following is the calculated Mean Time Between Failures (MTBF) at maximum configuration 
at 35
   C. These values are derived using a historical failure rate and multiplied by factors for 
application, electrical and/or thermal stress and for device maturity. MTBF estimates should be 
viewed as “reference numbers” only. 
 
Server Model 
Subassembly 
Base 
BRP 
LX 
(Server in 35°C  
ambient air) 
MTBF 
FIT 
MTBF 
FIT 
MTBF 
FIT 
  
(hours) 
(failures/10^
9 hrs) 
(hours) 
(failures/10^9 
hrs) (hours) 
(failures/10^9 
hrs) 
Power Supply (670W) 
220,000 
4,545 
  
  
  
  
Power Supply ( 830w + 
dist.module) 
  
  
380,000 
2,632 
380,000 
2,632 
Cooling fans( Non-
redundant) 250,000 
4,000 
250,000 
4,000 
  
  
Cooling fans( 
Redundant) 
  
  
  
  
125,000 
8,000 
Back Plane 
1,300,000 769 
1,300,000 769 
1,300,000  769 
Front Panel board 
5,000,000 200 
5,000,000 200 
5,000,000  200 
Intrusion Switch 
20,000,000 50 
20,000,000 50 
20,000,000  50 
Totals without 
motherboard = 
104,550 9,565 
130,700 7,651 8,5800 
11,651