act actpro iom 사용자 설명서
Technical Specification
Voltage 12V
DC
Current
Consumption
250mA
Communications
RS485
to
ACT2000/ACT3000
Operating
Temperature -10ºC
to
+50ºC
Mounting
Surface
Installation
Indoors
Weight
375g
Dimensions
190mm/137mm/58mm
Construction
Polycarbonate
housing
Product Overview
This product is an 8 Input/8 Output device that allows the ACT3000 and ACT2000 to
be used in applications where signalling to other equipment is required. Examples of
this are elevator control, alarm systems, CCTV switching and general monitoring.
A maximum of 4 I/O modules maybe connected to any single controller, giving
control of up to 32 relays and 32 inputs per ACT2000/ACT3000.
Features
• 8 form C relays
• 8 supervised inputs
• Tamper protection
• 2 status LEDs
• 2 status LEDs
• Timer for each output
• Input Timer
• Output switched ON/OFF by log event, input or timezone
• Output switched ON/OFF by log event, input or timezone
• ACTWinPro support
ACTWinPro Support
• Named inputs and outputs
• Inputs and outputs Logged
• Normally open/closed.
• Active on timezone
• Active on timezone
• Active on event, user, door or user group
• Active on input on/off
• Active on input on/off
• Active on output on/off
1