Using the Avaya Remote Supervisor Adapter
Alerts
Avaya Remote Supervisor Adapter User Guide
31
November 2003
Figure 10: Alerts
NOTE:
Please read the following notes before proceeding.
Before an SNMP Agent or an SNMP Trap alarm can be generated they must be enabled. Enable 
the SNMP Agent and the SNMP Trap using the Simple Network Management Protocol 
configuration screens found under the Network Protocols link.
The Serial Port under ASM Control must be configured before an alert can be generated over 
the serial port
You cannot separate the alert types that will be sent to alert recipients. All configured alert 
recipients receive every alert that is selected.
To send alerts to an Avaya service center over modem, select IBM Director over Modem from 
the Notification Method field.
To send alerts to an Avaya service center over LAN, select SNMP over LAN from the 
Notification Method field.
Configuring a remote alert recipient 
You can define up to 12 unique remote alert recipients. Each link for an alert recipient is labeled with the 
recipient name, notification method, and alert status.
To configure or view a remote alert recipient:
Select Alerts in the navigation pane. 
The Remote Alert Recipient screen displays the name, selected notification method, and status of 
enabled or disabled. You can configure a maximum of 12 alert recipients.