Preventative Maintenance
788
Preventive Maintenance
12.
Return to the Carriage Beam Position menu and select Move to Printing (Normal) to move the car-
riage beam height back to the normal position.
Preventive maintenance #5: Replace Ink Tubes
The following parts must be dispatched to the customer for installation by an onsite engineer: Q6702-
67011 (tube kit) and Q6702-60690 (Tubes Cleaning Kit) 
The tubes replacement procedure can be found on  page 693.
NOTE:
It is very important to reset the maintenance kit usage each time you perform 
preventive maintenance action See page 420.