HP designjet l65500 서비스 매뉴얼

다운로드
페이지 178
Tr
ou
bles
hooting
 Troubleshooting
175
SE Code: 93:11 - Unable to pressurize the IDS system
Description
It has not been possible to reach the working pressure in the IDs system. The IDS pumps ink towards the 
bag inside the intermediate tanks which push the ink out of through the ink tubes.
The pressurization value (in either of the two side) in normal working conditions is between 5.2-5.6 psi. 
If this value is not reached within 60 seconds of starting the pumps, the error is triggered.
Problem causes in order of importance
A.
Air leakage from any of the systems on either side of the printer.
B.
Air pumps not working
C.
Relief valves not closed.
D.
Air pressure sensors not working correctly
Corrective Action
Air leakage from any of the systems on either side of the printer
1.
Across the ISM, start the air pumps of both sides (diagnostics 4.15.5 and 4.15.6) and check for pos-
sible air leaks (tubes broken or pinched, air pressurization bottles not correctly closed, tubes not cor-
rectly connected. Repair as required
Air pumps not working
2.
While the air pumps are pumping air though the system, check they are all working correctly. 
Replace any pumps that are faulty  page 610.
Relief valves not closed
3.
Operate the relief valves with diagnostics 4.15.7 and ensure the correct operation, replace the 
valves if they do not work  page 618.
Air pressure sensors not working correctly
4.
Leave the pumps running from the previous test, and check the increment of pressure with diagnostics 
4.15.8. If there is no air leak and pressure does not raise, replace the ISS board.
SE Code: 93:12 - Ink system module set as not purged
Description 
the ink system is set as not purged and requires the purging procedure or the purging procedure has not 
been completed.
There two things that are used to trigger the error. The ISM normally is set as purged and the TRS is set 
as purged, the error is displayed when any of the two system are not set as purged.
ISM as purged is set after diagnostics utilities 0.1 Purge ISM and 0.2 fill Intermediate tanks are completed 
successfully. This as purged is set after diagnostics utility 0.3 Purge Printer tubes is completed successfully. 
The two parts can be reset by an unsuccessful refill utilities or by setting the printer for transportation and 
accepting transportation at low temperatures.
Problem causes in order of importance
A.
Purge not performed.
B.
Purge performed but not finished
C.
Purge completed via manual procedures.