HP proliant dl580 사용자 설명서
Server component identification 79
NOTE: The system management driver must be installed for the internal health LED to provide pre-failure
and warranty conditions.
LED Description
Fan X
One or more of the following conditions exist:
•
A fan is missing or not properly installed.
•
A fan failed.
PCI X
One or more of the following conditions exist:
•
A PCI address parity error was detected on the numbered PCI slot.
•
A PCI data parity error was detected on the numbered PCI slot.
SCSI BP
The SCSI backplane is missing or not properly installed.
MEM
A memory board is not properly installed.
MEM BP
A memory backplane is missing or not properly installed.
FSB
One or more of the following conditions exist:
•
A processor or PPM is missing or not properly installed.
•
An FSB configuration error was detected.
PROC
A processor is missing or not properly installed.