Troubleshoot the Cooling System
197
Chapter 17
Troubleshoot the Cooling System
The router’s cooling system comprises two separate subsystems: 
„ Upper and lower impeller assemblies—Cool the Packet Forwarding Engine components 
(backplane, SCB, FPCs, and PICs). The lower impeller assembly is located behind the 
craft interface at the front the chassis (see Figure 1), and the upper assembly is located 
above the fan tray at the rear of the chassis (see Figure 2). Each assembly houses two 
impellers for redundancy. The assemblies are not interchangeable.
„ Fan tray—Cools the Routing Engine and backplane. The tray houses three fans for 
redundancy and is located above the Routing Engine at the upper rear of the chassis (see 
Figure 2).
The cooling system draws in room air through the air intake vent located at the front of the 
chassis below the craft interface. After entering the chassis, the air stream separates into 
separate flows for the front and rear subsystems, and the temperature of each flow is 
monitored independently. For a graphic depiction of the airflow, see Figure 10.
For the cooling system to function properly, the clearance around the chassis must be 
sufficient for unobstructed airflow. See “Clearance Requirements for Airflow and Hardware 
Maintenance” on page 42.
During normal operation, the impellers and fans in the fan tray function at less than full 
speed. Sensors on the backplane and router components constantly monitor their 
temperature, and the speed of the fans and impellers is adjusted as necessary. If the router 
temperature exceeds the acceptable maximum, the JUNOS software shuts down the router 
by turning off the power supplies. 
To troubleshoot the cooling subsystems, follow these procedures: