Eaton PC125-A2-LT 사용자 설명서
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999
2
SPECIFICATIONS
PC125-A
PC125-A2
PC125-B
PC125-C
PC125-D
PC125-F
Approvals
UL
UL
UL
UL
UL
UL
Voltage Input/Output (50/60Hz)
120V~
120V~
240V~
120V~
120V~
240V~
Current Input
15A
20A
15A
30A
30A
30A
Current Output
12A
16A
12A
24A
24A
24A
Full Load VA
1440VA
1920VA
2880VA
2880VA
2880VA
5760VA
NEMA Outlets
5-15R
5-20R
6-15R
5-15R
5-20R
6-15R
Circuit Breaker
15A
20A
15/15A
15/15/30A
20/20/30A
15/15/30A
EMI/RFI Filter
20A
20A
20A
30A
30A
30A
Multi-Stage Surge Suppression
270V/150V
270V/150V
320V/270V
270V/150V
270V/150V
320V/270V
Cord/Length/Plug
14/3, 9’
12/3, 9’
14/3, 9’
10/3, 15’
10/3, 15’
10/3, 15’
NEMA Power Input Plug
5-15P
5-20P
N/A
L5-30P
L5-30P
L6-30P
Multiple Time Delay (MTD)
PC420-A
PC420-A2
PC420-B
PC420-C
PC420-D
PC420-F
RACK MOUNTED
•
19” x 3.4” (2U) x 8.5”.
•
Approximate shipping weight: 19 lbs.
(12) NEMA OUTLETS
•
4 unswitched and 8 switched via remote
(4) INDICATOR LIGHTS
•
(1) Main breaker power “ON”
•
(1) Power to unswitched outlets
•
(2) Power to switched outlets
POWER INPUT
•
Power cable with plug is attached to unit
through the rear panel cable grip
through the rear panel cable grip
EMI/RFI FILTERING
•
Common Mode Line to Ground
•
Differential Mode Line to Line
SPIKE/SURGE SUPPRESSION
•
L-N, L-G, N-G
LOCAL/OFF/REMOTE SWITCHING
•
Local: Power “on or off” to the switched
outlets
outlets
•
Off: When breaker is “on” but this switch is
in the “off” mode, you will have power to the
unswitched outlets only
in the “off” mode, you will have power to the
unswitched outlets only
•
Remote: Power “on or off” to the
switched outlets via a remote device
•
When using a Latching remote, the
selection switch is wired for
Remote/Off/Remote - There is no
local control
Remote/Off/Remote - There is no
local control
OVERLOAD CIRCUIT PROTECTION
•
Electromagnetic breaker
provides manual on/off switching and
provides manual on/off switching and
trips in an overload condition
(3 N/O) REMOTE I/O PORTS
•
Remote on/off and EPO control, EPO
overrides remote and local control
•
Sequence Power Up additional
equipment down line
equipment down line
•
“LT” units only: Latching remote -
(N/C) EPO, momentary start
(N/C) EPO, momentary start
MULTIPLE TIME DELAY(MTD)
TM
•
Section 1 powers on immediately
followed four seconds later by Section 2
•
Select PC420 in part number for MTD option
PC125-A-LT
PC125-A2-LT
PC125-B-LT
PC125-A2-LT
PC125-B-LT
PC125-C-LT
PC125-D-LT
PC125-F-LT
PC125-D-LT
PC125-F-LT
PC125-C Front