Denon avr-3300 ost-615 서비스 매뉴얼

다운로드
페이지 1
 
100 Corporate Drive Mahwah, NJ 07430
 
 
       
 
 
 
Service Bulletin
 
No
. :  OST-615 
Date:
 January 23, 2007 
_____________________________________________________________
 
 
Model:
 
AVR-3300   
 
 
 
 
 
 
 
Subject: 
The cooling fan is noisy. 
 
 
 
 
 
 
 
 
 
Symptom:
 The customer complains the cooling fan is too noisy. 
 
 
Solution: 
Lower the voltage to the Cooling Fan.  
Apply the following modification to the Regulator Unit (1U-3201-1): 
1)  Remove the Jumper-wire JV23 from the P.W.B. and replace it with an 82Ω, 
1W resistor. 
2)  Replace diode ZD901 (MTZ12A) with an MTZJ9.1CT77 style diode. 
 
 
Parts: 
 
Ref# Description 
Part 
Number 
JV23 
RS14B3A820JNBST(S) 
244 2055 983 
ZD901 
MTZJ9.1CT77 
276 0635 917 
 
 
 
 