Nokia 2650 서비스 매뉴얼

다운로드
페이지 72
ISSUE 1 09/2004
COMPANY CONFIDENTIAL
37
Copyright © 2004 Nokia. All Rights Reserved.
RH-53/54
Nokia Customer Care
 Receiver Troubleshooting
■ 
Front End Module (FEM) control signals
Depending on the vendor of the Front End Module (FEM), different timing of the control signals 
are present. The SW suppoerts both FEMs. R629 tells the SW which FEM control should be 
active. Renesas FEM control is used when R629 is 18K and RFMD FEM control is used when 
R629 is 82K.
If the FEM is exchanged with an other type, the R629 must be changed, too.
Renesa FEM logic
Table 5: Renesa FEM logic
RFMD FEM logic
Table 6: RFMD FEM logic
Mode
Vtx
BS
VC1
VC2
VTX_B_P
VTX_B_P
Vant1
Vant2
Low Band RX
0
0
0
0
Low Band TX
1
0
1
0
High Band RX
0
1
0
0
High Band TX
1
1
0
1
Vtx
BS
VC1
VC2
Mode
VTX_B_P
VTX_B_P
Vant1
Vant2
Idle
0
0
0
0
Low Band RX
0
0
1
0
Low Band TX
1
0
1
0
High Band RX
0
1
1
0
High Band TX
1
1
1
0