Panasonic AJ-SPX800E 사용자 설명서

다운로드
페이지 118
108
<Note>
The remaining battery capacity for digital batteries is displayed
as % inside the viewfinder (PRO14/TRIM14/HYTRON50/
HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50). 
The BATT NEAR END alarm, however, is triggered according to
the setting on the <BATTERY SETTING1> screen, regardless of
the % indication. 
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved 
Adjustable 
Range 
Remarks 
DIONIC90
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
13.6
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –
 DIONIC160
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
13.3
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –
HP-90L
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
12.4
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –
BP-H120
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
11.5
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –
NP-L50
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
13.0
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –
Items/
Data Saved 
Adjustable 
Range 
Remarks
ENDURA50
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection.  
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
13.1
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –
ENDURA80
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
13.5
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –
BP-L60/90
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
AUTO
MANUAL
Select auto or manual to set the NEAR END 
voltage. 
AUTO: Set voltage automatically. 
MANUAL: Set voltage manually. 
11.0
 : 
11.2
 : 
15.0
When MANUAL is selected in the menu 
above, set the NEAR END voltage in 0.1 V 
steps. 
– C U F –