Panasonic KX-TDE100 사용자 설명서

다운로드
페이지 252
1.4 Specifications
38
Installation Manual
PSU Capacity
Each PSU supports a different load figure.
Calculation Example (KX-TDE200)
The total load figure is 96. As this is between 64 and 128, you should install the PSU-M. But if you expect 
expansion in the future, it may be better to install the PSU-L. There is no harm in installing a PSU that is 
larger than is required for the current configuration.
PSU Type
Maximum Load Figure
PSU-S (for KX-TDE100 only)
64
PSU-M
128
PSU-L (for KX-TDE200 only)
512
Equipment Type
Load Figure
KX-T7600 series DPT
48 units
48
Other DPT
2 units
8
SLC16
1 card
16
MSLC16
1 card
16
VPS
8 ports
8
Total
96