Toshiba VF-A7 사용자 설명서

다운로드
페이지 50
 
 36
11.1 Setup Page 
The setup page is the initial page that is displayed when the unit’s IP address is 
accessed via a web browser.  Refer to Figure 11 for a screen shot of the setup page.  
This page contains the ETH-100’s basic identification and configuration parameters: 
 
Note that the ETH-100 requires valid user authentication whenever any configuration 
information is modified.  This will appear as a browser popup box that will request the 
user name and password.  The initial factory-set value for the username is “admin”, 
and the password is blank (i.e. do not enter a password).  Note that the username 
and password are case-sensitive, and that the authentication will remain in effect 
from that point until all browser windows are closed. 
 
 
Firmware Version: 
The current firmware version and the date it was created.
MAC Address: 
The unique 48-bit Ethernet MAC ID for this device. 
IP Address: 
The IP address of the device (i.e.: 10.0.0.100). 
Subnet Mask: 
The Subnet Mask of the device (i.e.: 255.255.255.0). 
Default Gateway: 
The Default Gateway of the device (i.e.: 10.0.0.2). 
Current Date & Time: 
The current date and time set on the device. 
Update Date & Time: 
To change the date: select the check box next to “Date”, 
change the date to the desired values, and click Apply.  If 
the check box is not selected, the values in the date 
fields will be ignored. 
 
To change the time: select the check box next to “Time”, 
change the time to the desired value, and click Apply. 
The time is represented in Military (24 hr.) format.  If the 
check box is not selected, the values in the time fields will 
be ignored. 
Username & Password: 
To change the authentication username for modifying the 
ETH-100’s configuration parameters: select the check 
box next to “Username”, type your desired user name 
(max 10 characters), and click apply.  You will be 
required to enter the current username and password to 
update your username to its new value.  Contact ICC if 
you cannot remember your username. 
 
To change the authentication password for modifying the 
ETH-100’s configuration parameters: select the check 
box next to “Password", type your desired password 
(max 10 characters), and click apply.  You will be 
required to enter the current username and password to 
update your password to its new value.  Contact ICC if 
you cannot remember your password. 
 
By clicking “cancel” before clicking “apply”, all configuration data will be reset to the 
last applied values.  Clicking “help” will open a new browser window displaying some 
basic help information.