Routing and Connecting Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork.
performance and reduce lint buildup and
condensation in the ductwork.
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
and must be purchased separately.
• Use 4-in. (10 cm) diameter rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as
possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct
must point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
buildup on duct surfaces.
buildup on duct surfaces.
IMPORTANT: Failure to exhaust the dryer
correctly will void the dryer's warranty.
correctly will void the dryer's warranty.
VENTING THE DRYER
(cont.)
Correct Venting
Incorrect Venting
I N S TA L L AT I O N I N S T RU C T I O N S
I N S TA L L AT I O N I N S T RU C T I O N S
Number of
Max. Length of 4-In. Dia.
Max. Length of 4-In. Dia.
Wall Cap Type
90° Elbows
Rigid Metal Duct
Flexible Metal Duct
0
65 ft. (19.8 m)
45 ft. (13.7 m)
1
55 ft. (16.8 m)
35 ft. (10.7 m)
2
47 ft. (13.7 m)
30 ft. (9.1 m)
3
36 ft. (11.0 m)
25 ft. (7.6 m)
4
28 ft. (8.5 m)
20 ft. (6.1 m)
0
55 ft. (16.8 m)
35 ft. (10.7 m)
1
47 ft. (13.7 m)
27 ft. (8.1 m)
2
41 ft. (12.5 m)
21 ft. (6.4 m)
3
30 ft. (9.1 m)
17 ft. (5.2 m)
4
22 ft. (6.7 m)
15 ft. (4.5 m)
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.