Controls and Functions
Front Panel
1
POWER/STANDBY switch and indicator
This is the main POWER switch. Press to turn on the 
amplifier. Press it again to turn off. The POWER indica-
tor lights up when the amplifier it turned on.
STANDBY operation can only be set from an external 
device, connected to the REMOTE terminal. When 
STANDBY is on, the indicator is lit in orange.
2
PROTECT/MUTE indicator
When the protection system is active, the PROTECT 
indicator lights up and the speakers are automatically 
disconnected from the amplifier’s outputs. The protec-
tion system activates in the following situations:
When the amplifier is turned on
The protection system activates for approximately 
three seconds when the amplifier is turned on. After 
three seconds, the protection system deactivates auto-
matically and the amplifier is ready for normal opera-
tion.
If a DC voltage is detected at the amplifier’s out-
puts
The protection system activates if a DC voltage is 
detected at the amplifier’s outputs. Once the DC volt-
age problem is corrected, the protection system deac-
tivates automatically and the amplifier is ready for 
normal operation.
If the amplifier overheats
When overheating occurs, the PROTECT/MUTE 
indicator lights. You should immediately turn off the 
amplifier and allow it time to cool down. See the Pre-
cautions section of this Owner’s Manual for ways to 
prevent the amplifier from overheating.
3
CLIP/LIMIT indicator
A channel’s CLIP indicator lights up when its output 
distortion exceeds 1% (i.e., clipping). Output signal 
clipping is typically caused by excessive input signal 
levels. When this happens, the limiter is engaged auto-
matically.
4
SIGNAL indicator
A channel’s SIGNAL indicator lights up when its output 
exceeds a certain amount (2V rms on the XM4180/
XM4080, 4V rms on the XH200.)
5
VOLUME controls
The channel volume controls have click detents for the 
settings, and each channel can be set over a range of -
∞ 
dB to 0 dB. On the XM4180 and XM4080, when the 
amplifier is set to bridged mode, only the first volume 
control on each channel pair is used (i.e., for the A/B 
pair, channel A is active, and for the C/D pair, channel C 
is active).
6
Air intakes 
The amplifier has a forced-air cooling fan that takes in 
air from the front and exhausts it from the rear. Make 
absolutely sure that these intakes are not obstructed.
Security cover
If you want to keep the volume settings from being 
modified, attach the included security cover using 
the screw holes shown below, so that the volume 
controls are inaccessible.
5
6
1
2
3
4
* The illustration shows model XM4180.
Air 
intake
Air 
exhaust
Front
Rear
* The illustration shows model XM4180/XM4080.