Technicolor - Thomson 8900NET 사용자 설명서

다운로드
페이지 72
60
8900NET  Instruction Manual
Service
 
5.
Check that the particular event has been enabled in the frame.
For all events, check that the STATUS switch (Switch 1) on the S2 
DIP switch block of the 8900NET module is Enabled.
For Module Failure-Fixed events: 
Check that the MODULE switch (Switch 5) on the S1 DIP switch 
block of the 8900NET module is Enabled, and
Check that the 
SLOT STATUS REPORTING
 parameter on the slot’s 
SLOT 
CONFIG
 page is Enabled. 
For Power Supply Failure-Fixed events:
Check that the PS1 or PS2 switch (Switch 1 or 2) on the S1 DIP 
switch block of the 8900NET module is Enabled, and 
Check that the 
POWER SUPPLY STATUS REPORTING
 parameter on the 
power supply’s 
CONFIGURATION
 page is Enabled. 
For 8900NET module Failure-Fixed events, check that the 
NET CARD 
STATUS REPORTING
 parameter on the 8900NET module’s 
CONFIGURA-
TION
 page is Enabled. 
For Hardware Switch change events, check that the 
HARDWARE 
SWITCH REPORTING
 parameter on the 8900NET module’s 
CONFIGURA-
TION
 page is Enabled. 
For Frame Bus Failure-Fixed events: 
Check that the FRAME BUS switch (Switch 6) on the S1 DIP switch 
block of the 8900NET module is Enabled, and 
Check that the 
FRAME BUS STATUS REPORTING
 parameter on the 
frame’s 
CONFIGURATION
 page is Enabled. 
For Front Cover Removed -Installed events, check that the 
COVER 
STATUS REPORTING
 parameter on the frame’s 
CONFIGURATION
 page is 
Enabled. 
For Frame Bus Failure-Fixed events: 
Check that the FRAME BUS switch (Switch 6) on the S1 DIP switch 
block of the 8900NET module is Enabled, and 
Check that the 
FRAME BUS STATUS REPORTING
 parameter on the 
frame’s 
CONFIGURATION
 page is Enabled. 
For Cooling Fan Failure-Fixed events: 
Check that the FAN switch (Switch 4) on the S1 DIP switch block of 
the 8900NET module is Enabled, and 
Check that the 
FAN STATUS REPORTING
 parameter on the frame’s 
CON-
FIGURATION
 page is Enabled. 
For Module Health Failure-Fixed events, 