Epson S1C62 Family 사용자 설명서

다운로드
페이지 219
SEGMENT OPTION GENERATOR SOG62XX
VI-8
EPSON
S1C62 FAMILY
DEVELOPMENT TOOL REFERENCE MANUAL
4.4 HEX File Generation and EPROM Selection
When input file selection is completed, the following message is output to ask the operator whether to
generate the HEX file.
END OF OPTION SETTING.
DO YOU MAKE HEX FILE (Y/N) ? Y
. . (1)
*** OPTION EPROM SELECT MENU ***
        1. 27C64
        2. 27C128
        3. 27C256
        4. 27C512
PLEASE SELECT NO.? 2
. . (2)
        2. 27C128   SELECTED
(1) DO YOU MAKE HEX FILE (Y/N)?
When debugging the program with evaluation board, HEX file C2XXYYYS.HEX is needed, so enter "Y".
If "N" is entered, no HEX file is generated and only document file C2XXYYYS.DOC is generated.
However, when H option is used, HEX file is generated without any conditions. Therefore, this menu is
not displayed.
(2) PLEASE SELECT NO.?
For the option ROM selection menu displayed when "Y" is entered in Step (1), select the EPROM to be
used for setting evaluation board options. This menu is not displayed when "N" is entered in Step (1).
"27C128" is selected in the above example.
When the above operation is completed, SOG62XX generates files. If no error is committed while setting
segment options, the following message is output and the SOG62XX program will be terminated.
MAKING FILE IS COMPLETED.
Note
The EPROM to be mounted on the evaluation board must satisfy the following conditions:
EPROM for setting segment option:Tacc 
 170 ns (Tacc: Access time)
4.5 End Procedure
When a series of operations are complete, the SOG62XX program will be terminated.
SOG62XX can be forcibly terminated by pressing the "CTRL" and "C" keys together during program