Planning Information
Wolf Ventilation  Recommendations
8
Dimensions in parentheses are in
millimeters unless otherwise specified.
P R O   V E N T I L A T I O N   C F M R E C O M M E N D A T I O N S
Pro Island Hoods
I363418
I423418
I543418
I663418
DF304 / R304 / SRT304
600
600
DF366 / R366 / SRT366 / RT366
900
DF364 / R364 / SRT364 / RT364
900
RT362
900
R488 / RT488
1100
DF486 / R486 / SRT486 / RT486
1100
DF484 / R484 / SRT484 / RT484
900
R482 / RT482
900
DF606 / R606
1500
DF604 / R604
1500
Model numbers for dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops indicate width and number of surface
burners. Features such as a charbroiler, griddle and/or French Top will vary.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be
required for long duct runs.
P R O   V E N T I L A T I O N   B L O W E R   O P T I O N S
Pro Island Hoods
Blower Description
Blower Number
Island Hood Models
1200 CFM Internal
IBLOWER-120INT (804703)
All Island Hoods
1100 CFM In-Line
BLOWER-110IL (808332)
All Island Hoods
900 CFM Remote
BLOWER-90REM (801641)
I363418 / I423418 / I543418
1200 CFM Remote
BLOWER-120REM (801642)
All Island Hoods
1500 CFM Remote
BLOWER-150REM (804701)
All Island Hoods
Vertical discharge with 10" (254) round duct.
Island hood models without decorative rails listed; blower options are the same for (R) models. Transition with backdraft damper
included with island hoods. Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific
cooking product. Always consult a qualified HVAC Engineer for specific applications.