Sun Microsystems enterprise server 220r 사용자 설명서

다운로드
페이지 208
Chapter 4
Hardware Configuration
87
You must include the Sun Enterprise 220R server internal bus length of 2.952 feet
(0.9 meter) in your bus length calculations.
For fast/wide performance on the external SCSI bus, the maximum Sun-supported
SCSI bus length for daisy-chained SCSI devices is 6 meters (19.7 feet), including the
Sun Enterprise 220R internal bus length.
UltraSCSI devices can be mixed with non-UltraSCSI devices on the same bus. The
UltraSCSI devices will still operate at UltraSCSI speeds (40 Mbytes/sec), provided
that the rules for UltraSCSI cabling, bus length, termination, and target devices are
followed.
If all external SCSI devices use 68-pin connectors, connect all non-Sun devices to the
system first and connect a Sun autoterminating device to the end the chain.
If external mass storage devices consist of 68-pin devices and 50-pin devices, connect
the Sun 68-pin devices to the system first and terminate the chain with a 50-pin
device and its terminator. The 68-pin device connected to the 68-50 pin adapter cable
must be autoterminating in order to terminate the high-order bits.
If you install an internal tape drive into the system, you should assign it target
address 4 or 5. If you install an internal CD-ROM into the system, you should assign
it target address 6. If these drives have been factory-installed, they are configured
with the correct addresses for the system.
The removable media SCSI cable provides the termination for the internal SCSI bus.