Parker Hannifin mx80l precision grade 사용자 설명서

다운로드
페이지 40
MX80L Series Product Manual  
 
Chapter 3 - How to Use the MX80 
 
Parker Hannifin Corporation
28 
 
•  Catalog specifications may deviate for positioners mounted to surfaces that do not meet the above 
conditions.  
•  If the intended mounting surface cannot meet these specifications a separate rigid mounting plate 
meeting these specifications should be used to mount to the main structure.  
 
•  If mounting conditions require that the table base is overhung, table specifications will not be met 
over that portion of the table. Additionally, in X-Y Systems the overhung portion of the Y-axis may 
not met specifications due to the additional error caused by deflection and non-support of the 
base. Contact Daedal for guidelines on specifications of overhang applications 
 
Load Mounting Requirements
  
 
Dowel holes are included in the carriage of the MX80L for repeatable mounting of loads/fixturing.  When 
bolting payload to carriage take precaution in using bolts M4 with 7mm of engagement as to not damage 
the table. 
 
 
Use appropriate length bolt.
 
The MX80L compact design requires proper sized bolts to be used when mounting payloads to the 
carriage.  Excessive length bolts can damage bearings or pin the table in position.     
Daedal Division 
Irwin, Pennsylvania