MX80L Series Product Manual  
 
Chapter 1 - Introduction 
 
Parker Hannifin Corporation
Specification Conditions 
       
Specifications Are Temperature Dependent 
Catalog specifications are obtained and measured at 20 Degrees C. Specifications at any other 
temperature may deviate from catalog specifications. Minimum to maximum continuous operating 
temperature range (with NO guarantee of any specification except motion) of a standard unit before 
failure is 5 - 40 degrees C.  
 
Specifications Are Mounting Surface Dependent 
Catalog specifications are obtained and measured when the positioner is fully supported, bolted 
down, and is mounted to a work surface that has a maximum flatness error of: 
•  Standard Grade: 0.003mm/300mm (0.0001”/ft) 
•  Precision Grade: 0.001mm/300mm (0.00004”/ft) 
Table will operate with work surface 0.100mm/300mm but performance specifications will be 
significantly effected. 
 
Specifications Are Point of Measurement Dependent 
Catalog specifications and specifications in this manual are measured from the center of the carriage, 
38 mm above the carriage surface. All measurements taken at any other location may deviate from 
these values. 
 
 
 
 
 
 
 
 
 
 
 