MX80L Series Product Manual  
 
Chapter 3 - How to Use the MX80 
 
Parker Hannifin Corporation
32 
repeatability the final homing speed must be slow. Slower final speed usually results in higher 
repeatability. 
 
NOTE: The “Z” channel output is only one resolution count wide. Thus the on-time may be very brief.  
Due to this some controllers may have difficulty reading the signal. If you are experiencing the positioner 
not finding the “Z” channel during homing, try reducing final homing speed; also refer to your controller 
manual for frequency rates of the “Z” channel input. 
 
Grounding / Shielding  
 
All cables are shielded. These shields are to be grounded to a good earth ground. Failure to ground 
shields properly may cause electrical noise problems. These noise problems may result in positioning 
errors and possible run away conditions. 
The motor cable has an area of the shield exposed to allow a grounding path from shield to drive ground.  
The Hall/Encoder and Limit/Home cables have the shield carried through the connector hood that is in 
turn grounded through the drive. MX80L purchased with ViX drives as part of the configurable part 
number come equipped with p-clips designed for the small OD of the motor cable to allow the cable 
shield to be grounded to the ViX ground. 
  
Cabling 
 
The MX80L is provided with high flex cabling which is strain relieved at the connection point on the 
positioner. The Hall/Encoder cable is terminated with a high density 15 pin D-sub connector which is 
compatible with the ViX drive from Parker. The motor cable is terminated with flying leads which are 
stripped and tinned and ready for installation into the screw terminals on the ViX drive. For wire color 
codes and pin outs see tables in electrical section of manual. 
 
The limit/home cable is optional and therefore if not ordered a space will be open in the clamp at the 
connection point.  The limit/home cable is provided with a 15 pin D-sub connector which is compatible 
with the ViX drive. For wire color codes and pin outs see tables in electrical section of manual. 
 
Recommended bend radius for these cables is 50mm. This radius will provide a minimum of 10 million 
cycles of the cable. Smaller bend radius will reduce cable life while larger bend radius will increase life.   
 
If the positioner is mounted in a multi-axis configuration special care should be taken in routing and strain 
relieving the cables so as to prevent flexing of the cable at the connection to the table and where 
mounted stationary to the structure. Provide sufficient service loop that the cable bends a minimum of 
25mm from these end points. It is also recommended to avoid twisting the cable. The cable should be 
secured in a position which will orient it in a direction that creates a single plane of operation for the 
cable. 
 
To replace extension cables 1.) Disconnect power to positioner.  2.) Remove two button head screws 
from side of shield and remove the shield.  3.) Remove the two cap head screws from the strain relief 
and remove the strain relief.  4.) unplug extension cables.  5.) Reverse steps to reassemble.   
Note
: When reassembling the strain relief, take care not to pinch any wires and be certain that the 
exposed braided shield on the cables lies under the strain relief. 
 
                         
     
   
 