Installation to Solid Concrete or Cinder Block
Make sure that wall plate (A) is level, use it as a 
template to mark six mounting holes. The top mounting 
slots should be located 7" (177 mm) above the desired 
screen center as shown in figure 1.1 page 4. Drill six 
5/16" (8 mm) dia. holes to a minimum depth of 2.5" 
(64 mm). Insert anchors (D) in holes flush with wall 
as shown (right). Place wall plate over anchors and 
secure with six wood screws (C). Level, then tighten all 
fasteners.
C
A
D
solid concrete
cinder block
1
•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete 
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid 
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to 
avoid breaking out the back of the hole when entering a void or cavity.
•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Installer must verify that the supporting surface will safely support the combined load of the equipment and all at-
tached hardware and components.
WARNING
•  Tighten screws so that wall plate is firmly attached, 
but do not overtighten. Overtightening can damage 
screws, greatly reducing their holding power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
•  Always attach concrete anchors directly to load-
bearing concrete.
•  Never attach concrete anchors to concrete covered 
with plaster, drywall, or other finishing material. 
If mounting to concrete surfaces covered with a 
finishing surface is unavoidable, the finishing surface 
must be counterbored as shown below. Be sure 
concrete anchors do not pull away from concrete 
when tightening screws. If plaster/drywall is thicker 
than 5/8", custom fasteners must be supplied by 
installer (not evaluated by UL).
WARNING
CUT
A
W
A
Y
 VIEW
INCORRECT
CORRECT
wall 
plate
wall 
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
D
Drill holes and insert anchors (D).
Place plate (A) over anchors (D) and secure with screws (C).
Tighten all fasteners.
A
K
D
C
concrete 