5. Quick Overview Test - With the entire display flashing, this 
cycle is started by pressing the WOOLENS key pad. This 
cycle provides a quick verification that the cold and hot water 
valves, dispensers, and pump motor are working, as well as 
actuator dispenser movement. It also includes door lock, 
drain, and spin operations. 
Pressing the DELICATES AND KNITS key pad will exit diagnostic 
mode and cancel a diagnostic cycle in process. 
DIAGNOSTIC CODES
If the set-up mode is entered and one of the following has 
occurred, the appropriate diagnostic code will be in the display. 
d5
Blocked coin 1 or coin drop control circuit failure (coin 
recognition and price display disabled while blockage 
persists). PN Models Only: Set-up mode J. should be 
set to _d (or Ed if in free operation mode) to eliminate 
coin related diagnostic codes. 
d9
Low voltage detected for 8 seconds.
d13
Blocked coin 2 or coin drop control circuit failure 
 
(coin recognition and price display disabled while 
blockage persists).
F20
Slow Fill. The washer will not detect water input for 
4 min. Pressure switch failure or no water inlet. This 
code is reported as d8 on d7.
F22
The door is not able to lock. Door lock error or 
someone trying to start the washer, by pressing the 
door switch with the finger. This code is reported as 
d17 on Accu Trac. 
(For different code consult service personnel)
WASHER HELP MODE
This mode is entered by pressing the PERMANENT PRESS key 
pad while in special pricing option mode 2.XX (or while dAS 
displays if operating with Maytag Data Acquisition set-up).
In help mode, other display symbols and elements are mapped 
 
to reflect the state of various inputs and outputs as follows: 
Display Symbol
Description
Wash
Water sensed at wash level.
*
Low voltage present (below about 
90 VAC).
° (Circle above digit)
Door closed.
DOOR LOCKED
Door sensed locked.
COLD
Cold water relay on.
HOT
Hot water relay on.
OR
Door unlock. 
AVAILABLE
Drain pump ON.