Operating The Tool
(Continued)
3. For deeper penetration, turn the
wheel (C) to left to the extent
desired.
4. Make sure trigger
and work contact
element (WCE) move
freely up and down
without binding or
sticking after each adjustment.
ADJUSTING THE DIRECTION OF THE
EXHAUST
The MXN104 is
equipped with an
adjustable direc-
tion exhaust
deflector. This is
intended to allow
the user to change the direction of the
exhaust. Simply twist the deflector to
any direction desired.
CLEARING A JAM FROM THE TOOL
1. Disconnect the
air supply from
the tool.
2. Remove all fas-
teners from the
magazine (see
Loading/
Unloading).
Failure to remove
all fasteners will
cause the fasteners to eject from the front
of the tool.
3. Undo hook by
pushing down on
the button on the
side of the maga-
zine. The button
will disengage the hook from the
nose.
!
WARNING
4. The door can now
be rotated, expos-
ing the jammed
fastener.
5. Remove the
jammed fas-
tener, using
pliers or a
screwdriver if
required.
6
Rotate door back 
into the closed 
position.
7. Push button
down again to lift
thehook. Close
the door and
release the button
to reengage the hook with the
nose.
8. Make sure the trig-
ger and work con-
tact element (WCE)
move freely up and
down without stick-
ing or binding.
Technical Support
Please call our Tool Hotline at 
1-888-241-5858 with any questions
regarding the operation or repair of
this tool or for additional copies of this
manual.
Fastener And Replacement
Parts
Use only
18 gauge fasten-
ers (or equivalent - see Fastener
Interchange Information). Tool perfor-
mance, safety and durability could be
reduced if improper fasteners are used.
When ordering replacement parts or
fasteners, specify by part number.
Tool Repair
Only qualified personnel should repair
the tool, and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and acces-
sories which perform equivalently.
Assembly Procedure For
Seals
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. 
!
WARNING
MXN10400
Operating Instructions
5
Rotate
movement
movement
BUILT TO LAST
Operating The Tool
(Continued)
3. Use a pressure
regulator on the
compressor, with
an operating
pressure of 0 -125
psi. A pressure regulator is required
to control the operating pressure of
the tool between 60 and 100 psi. 
SINGLE SEQUENTIAL MODE
This mode
requires the trig-
ger to be pulled
each time a fas-
tener is driven.
The tool can be actuated by depressing
the WCE against the work surface fol-
lowed by pulling the trigger. 
The trigger must be released to reset
the tool before another fastener can
be driven.
CHECKING THE WORK CONTACT
ELEMENT (WCE)
Check the opera-
tion of the Work
Contact Element (WCE) trip mechanism
before each use. The WCE must move
freely without binding through its
entire travel distance. The WCE spring
must return the WCE to its fully extend-
ed position after being depressed. Do
not operate the tool if the WCE trip
mechanism is not operating properly.
Personal injury may occur.
1. Disconnect the
air supply from
the tool.
2. Remove all fas-
teners from
the magazine
(see Loading/
Unloading).
3. Make sure the trig-
ger and work con-
tact element (WCE)
move freely up and
down without stick-
ing or binding.
!
CAUTION
tion) into the magazine.  Make sure
the pointed ends of the fasteners
are resting on the bottom ledge of
the magazine when loading.  Make
sure the nails are not dirty or dam-
aged.
3b. For staples, load a clip of staples
with the crowns straddling the mag-
azine rail.
4. Push the maga-
zine cover for-
ward until latch
button pops
up.
5. Always unload all fasteners before
removing tool from service.
Unloading is the reverse of loading,
except that you must disconnect
the air supply before unloading.
ADJUSTING THE FASTENER PENE-
TRATION
The tool is equipped with an adjustable
depth of drive feature. This allows the
user to determine how deep a fastener
will be driven into the work surface.
1. Adjust operating pressure so fasten-
ers are driven consistently. Do not
exceed 100 psi.
2. For shallow penetration, turn the
wheel (C) to right to the extent
desired.
4. Reconnect air
supply to the
tool.
5. Depress the Work
Contact Element
(WCE) against the
work surface with-
out pulling the trig-
ger. The tool MUST NOT OPERATE.
Do not use the tool if it operates
without pulling the trigger.
Personal injury may result.
6. Remove the tool
from the work sur-
face. The Work
Contact Element
(WCE) must return to
its original down
position. The tool MUST NOT
OPERATE
. Do not use the tool if it
operates while lifted from the work
surface. Personal injury may result.
7. Pull the trig-
ger and
depress the
work contact
element
(WCE) against the work surface. The
tool MUST NOT OPERATE.
8. Depress the
Work Contact
Element
(WCE) against
the work sur-
face. Pull the trigger. The tool
MUST OPERATE.
An improperly
functioning tool
must not be used. Do not actuate the
tool unless the tool is placed firmly
against the work piece.
LOADING/UNLOADING THE TOOL
1. Always connect the tool to the air
supply before loading fasteners.
2. Push down
on the latch
button.  Pull
back on the
magazine
cover.
3a. For nails, insert a
stick of Campbell
Hausfeld nails or
equivalent (see
"Fasteners" sec-
!
WARNING
MXN10400
Operating Instructions
4
movement
1
2
1
2
Latch
Button
Magazine rail
(C)