• Command table
00
Send frequency data
01
Same as 
Send mode data
command 06
02
Read band edge frequencies
03
Read operating frequency
04
Read operating mode
05
Set frequency data
06
00
Select LSB
01
Select USB
02
Select AM
03
Select CW
04
Select RTTY
05
Select FM
07
Select CW-R
08
Select RTTY-R
07
Select VFO mode
B0
Exchange main and sub readouts
B1
Equalize main and sub readouts
C0
Turn the dualwatch OFF
C1
Turn the dualwatch ON
D0
Select main readout
D1
Select sub readout
08
Select memory mode
0001–0101*
1
Select memory channel
*
1
P1=0100, P2=0101
09
Memory write
0A
Memory to VFO
0B
Memory clear
0E
00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
∂F scan start
12
Fine programmed scan start
13
Fine ∂F scan start
22
Memory scan start
23
Select memory scan start
0E
A1–A7
Set ∂F scan span (A1=±5 kHz,
A2=±10 kHz, A3=±20 kHz,
A4=±50 kHz, A5=±100 kHz, 
A6=±500 kHz, A7=±1 MHz)
B0
Set as non-select channel
B1
Set as select channel
D0
Set scan resume OFF
D3
Set scan resume ON
0F
00
Turn the split function OFF
01
Turn the split function ON
10
00
Select 10 Hz (1 Hz) tuning step
01
Select 100 Hz tuning step
02
Select 1 kHz tuning step
03
Select 5 kHz tuning step
04
Select 9 kHz tuning step
05
Select 10 kHz tuning step
06
Select 12.5 kHz tuning step
07
Select 20 kHz tuning step
08
Select 25 kHz tuning step
11
00
Attenuator OFF
06
Attenuator ON (6 dB)
12
Attenuator ON (12 dB)
18
Attenuator ON (18 dB)
12
00
Select/read antenna selection
01
(00=ANT1, 01=ANT2 : Add 0 or 1
to turn 
[RX ANT]
OFF or ON, re-
spectively.)
13
00
Announce with voice synthesizer
01
(00=all data; 01=frequency and 
02
S-meter level; 02=receive mode)
14
01 + Level data
[AF]
level setting (0=max. CCW to
255=max. CW)
02 + Level data
[RF]
level setting (0=max. CCW to
255=11 o’clock)
03 + Level data
[SQL]
level setting (0=11 o’clock to
255=max. CW)
06 + Level data
[NR]
level setting (0=min. to
255=max.)
07 + Level data Inside 
[TWIN PBT]
setting or IF
shift setting (0=max. CCW,
128=center, 255=max. CW)
08 + Level data Outside 
[TWIN PBT]
setting 
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data
[CW PITCH]
setting (0=low pitch
to 255=high pitch)
0A + Level data
[RF POWER]
setting (0=mini. to
255=max.)
0B + Level data
[MIC GAIN]
setting (0=mini. to
255=max.)
0C + Level data
[KEY SPEED]
setting (0=slow to
255=fast)
0D + Level data
[NOTCH]
setting (0=low freq. to
255=high freq.)
0E + Level data
[COMP]
setting (0=mini. to
255=max.)
0F + Level data
[BK-IN DELAY]
setting (0=short
delay to 255=long delay)
10 + Level data
[BAL]
level setting (0=max. CCW,
128=center, 255=max. CW)
12 + Level data
[NB]
level setting (0=mini. to
255=max.)
15 + Level data Monitor gain setting (0=0% to
255=100%)
16 + Level data VOX gain setting (0=0% to
255=100%)
17 + Level data Anti-VOX gain setting (0=0% to
255=100%)
18 + Level data LCD contrast setting (0=0% to
255=100%)
19 + Level data LCD bright setting (0=0% to
255=100%)
15
01
Read squelch condition
02
Read S-meter level
11
Read Po meter level
12
Read SWR meter level
13
Read ALC meter level
14
Read COMP meter level
16
02
Preamp (0=OFF; 1=preamp 1;
2=preamp 2)
12
AGC selection (1=Fast; 2=Mid;
3=Slow)
Command
Sub command
Description
Command
Sub command
Description
111
16
CONTROL COMMAND