ICOM ic-756pro3 사용자 설명서

다운로드
페이지 124
61
5
FUNCTION FOR RECEIVE
IF filter selection
The transceiver has 3 passband width IF filters for
each mode. 
For SSB and CW modes, the passband width can be
set within 50 to 3600 Hz in 50 or 100 Hz steps. A total
of 41 passband widths are available. 
For RTTY mode, the passband width can be set within
50 to 2700 Hz in 50 or 100 Hz steps. A total of 32
passband widths are available.
For AM and FM modes, the passband width is fixed
and 3 passband widths are available.
The filter selection is automatically memorized in
each mode.
The PBT shift frequencies are automatically memo-
rized in each filter.
[FILTER]
• IF filter selection
q Select the desired mode.
w For RTTY mode, turn OFF the RTTY filter by push-
ing 
[RTTY FIL]
.
e Push 
[FILTER]
several times to select the IF filter
1, 2 or 3.
• The selected passband width and filter number is dis-
played in the LCD.
• Filter passband width setting
(SSB, CW and RTTY mode only)
q Select SSB, CW or RTTY mode.
• Passband widths for AM and FM modes are fixed and
cannot be set.
w For RTTY mode, turn OFF the RTTY filter by push-
ing 
[RTTY FIL]
.
e Push 
[FILTER]
for 1 sec. to enter filter set mode.
r Push 
[FILTER]
several times to select the desired
IF filter.
t While pushing 
[(F-1)BW]
, rotate the tuning dial to
set the desired passband width.
• The passband width can be set within the range as
shown right table.
• Push 
[(F-3)DEF]
for 1 sec. to select the default value.
y Repeat steps r to t if desired.
u Push 
[EXIT/SET]
to exit the filter set mode screen.
The PBT shift frequencies are cleared when the
passband width is changed.
This filter set mode screen graphically displays the
PBT shift frequencies and CW pitch operations.
*: When the IF filter is selected FIL2 or FIL3 in the FM
mode operation, the Tx IF filter’s passband width is
fixed narrow selection (2.5 kHz).
FIL1
Mode
Filter
Default
Range (Steps)
3.0 kHz
1.8 kHz
2.4 kHz
1.2 kHz
250 Hz
7.0 kHz
500 Hz
2.4 kHz
250 Hz
500 Hz
9.0 kHz
3.0 kHz
6.0 kHz
10 kHz
Fixed
Fixed
15 kHz
50–500 Hz (50 Hz)/
600–3.6 kHz (100 Hz)
50–500 Hz (50 Hz)/
600–3.6 kHz (100 Hz)
50–500 Hz (50 Hz)/
600–2.7 kHz (100 Hz)
FIL2
SSB
RTTY
AM
FM*
SSB-D
CW
FIL3
FIL1
FIL2
FIL3
FIL1
FIL2
FIL3
FIL1
FIL2
FIL3
FIL1
FIL2
FIL3
BW
BW
DEF
DEF
SFT
SFT
0
FIL2
FIL2
U S B
U S B
TX
TX
VFO
VFO
USB
USB
USB
USB
USB
USB
FIL2
FIL2
qr.qot.pp
qr.wpt.pp
14.100.00
14.100.00
14.100.00
14.100.00
1
1
VFO
VFO
BW
BW
2.4k
2.4k
FILTER
FILTER
SSB
SSB
FI
FIL 1
FI
FIL 2
FI
FIL 3
3 . 0 k
3 . 0 k
2 . 4 K
2 . 4 K
1 . 8 K
1 . 8 K
PBT2
PBT2
PBT1
PBT1
3 0 0
3 0 0
1 5 0 0
1 5 0 0
2 7 0 0
2 7 0 0
ANT
ANT
1
COMP
COMP
OFF
OFF
WIDE
WIDE
METER
METER
Po
Po
P.AMP
P.AMP
1
AGC
AGC
MID
MID
ATT
ATT
OFF
OFF
VOX
VOX
OFF
OFF
qw:pp
12:00
Passband
width
Selected
IF filter