This configuration view has 15 parameters (configuration requires proven network 
information, it can not be validated by the DAServer): 
 
 
Enter Controller’s Network Address - to each network in the OMRON system 
can be assigned an unique network address between 0 and 127. When 
communicating with a node on another (remote) network, the entered value must 
be consistent with the network address (non-zero) assigned in the routing tables. 
The network address of 0 indicates the local network. Note: The default Network 
Address is 0. 
 
 
Enter Controller’s Node Address - each OMRON Controller in Ethernet network 
must have its own unique node address between 1 and 126 (if Controller is inter-
networked via other OMRON FA network then Node Address can have different 
range. For example, if inter-networked via SYSMAC LINK network, the Node 
Address range is between 1 and 62. Care should be taken to select a node 
address that will not conflict with other devices in the system. 
 
Note: If destination node is OMRON PLC with Ethernet Unit installed then Controller 
Node Address
 must be configured according to following rules: 
- if automatic conversion of Ethernet Unit’s IP address is used (also the node number 
setting rotary switch on the front panel of the Ethernet Unit is used) then Controller 
Node Address
 must  be equal with the fourth byte (octet) of local IP address of 
Ethernet Unit;  
- if automatic conversion of Ethernet Unit’s IP address is not used (IP Address Table 
is used) then Controller Node Address must  be equal with the Node number 
configured in the Ethernet Unit’s IP Address Table.  
 
 
Enter Controller’s IP Address. The Controller’s IP Address must match with IP 
address configured at corresponding controller Ethernet Unit system setup. 
 
 
Enter Controller’s Port Number. Enter the UDP Port Number used for 
communications with this OMRON controller. The Port Number must much with the 
Port Number set in the OMRON controller by appropriate Ethernet Unit 
configuration software. Note: The default port number is 9600. 
 
 
Enter Computer’s Network Address - the Local Network Address: the unique 
network address between 1 and 127 is assigned to each OMRON Ethernet 
network in the system. The entered value must be consistent with the network 
address assigned in the routing tables. When communicate only with nodes in the 
local network, you can set this Address to zero (default value). 
 
 
Select the Controller Series. The available series are: CS1/CJ1, C200HX/HG/HE, 
CV-series, C/CPM2X and CQM1. To select Controller Series, click on the combo 
box button and make your choice from the list. Note: Only PLCs of CS1/CJ1, 
C200HX/HG/HE and CV series are directly accessible in Ethernet network. All 
other series PLCs must be inter-networked to get data from them. 
 
 
Select Controller type. To select Controller type, click on the combo box button 
and make your choice from the list. The available types depends on selection in 
Controller Series combo box:  CS1/CJ1 series offers 2 options (CS1 and CJ1), 
C200HX/HG/HE series offers one option (C200HX/HG/HE), CV-series offers 5 
options (CV500, CVM1-CPU01-E, CV1000, CV2000 and CVM1-CPU11-E),