GTO pro-sl 51006100 사용자 설명서

다운로드
페이지 31
23
GTO Inc., Tallahassee, FL
12345678
ON
SWNG/SLD
MAST/SLV
GATE R/L
SEQUENC 1
SEQUENCE 2
TMR. OFF/ON
NORM/LEARN
OPEN/CLOSE
EDGE 6
EDGE 5
EDGE 4
EDGE 3
EDGE 2
EDGE 1
COM
COM
DUAL GATE
INTERFACE
RX
TX
GRN
RED
BLK
GTO
RCVR.
+
+
CYCLE
FREE
EXIT
CLOSE
OPEN
FIRE
DEPT.
SHAD.
LOOP
SAFETY
LOOP
ENTRY
LOOP
EDGE 6
EDGE 5
EDGE 4
EDGE 3
EDGE 2
EDGE 1
COM
COM
DUAL GATE
INTERFACE
RX
TX
GRN
RED
BLK
GTO
RCVR.
+
+
CYCLE
FREE
EXIT
CLOSE
OPEN
FIRE
DEPT.
SHAD.
LOOP
SAFETY 
LOOP
ENTRY
LOOP
Dual Gate Interface
Auxiliary Control Board 
(SLV)
Master Control Board 
(MAST)
Use 22 AWG (minimum) 
individually shielded
paried direct burial wire 
manufacured by Belden
Inc. to connect the two
units.
Set DIP Switches
for Slide Gates
Set 
MAST/SLV switch on each operator – 
one for master and the other for slave
Set 
GATE R/L switch on each operator – 
R for the gate that opens to the right 
L for the gate that opens to the left
GND
GND
ONLY BELDEN® type 8723,
 22 AWG 2-pair shielded
(with one ground) wire is
compatible with the DUAL
GATE INTERFACE terminal.
Ground wire is unshielded (bare).
The DUAL GATE INTERFACE RX TX terminal requires 22 AWG direct burial wire manufactured
by Belden Inc.  
BELDEN WIRE
®
    is the ONLY wire compatible with this terminal.  If another
manufacturer’s wire is connected, the DUAL GATE INTERFACE terminal will NOT FUNCTION!
BELDEN WIRE
® 
must be run through its own PVC conduit to protect it from damage.  BELDEN
WIRE
®
 should NEVER be run in conduit containing ac wiring!
All four (4) connectors plus one (1) COMMON must be wired.
NOTE: A separate gate or entrance must be installed for pedestrian use.