Gianni Industries DG-30 사용자 설명서

다운로드
페이지 4
 
Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG30  Ver. A  Publish:2004.08.26                                                             Page: 3/ 4
 
‹
 Followed 
By 
03」:This will set the system to be used as : Slots 001~150 for PIN 
codes only 
 
Note:
 
When system format has the change, there’s a possibility the card stored would be 
invalid. Please reset the system and input all cards /tokens. 
  
‹
  Add card and deletion  
       
Enter the Programming mode, Enter the slot position code 「001~100」  
A. 
Green
 light comes on:
 This slot position is ready to register the card 
1. 
Present card in front of the readerÆYellow LED blinks (beep) Æ enrolled 
completed Æ(repeat) 
2. 
Present card in front of the readerÆ (3 audible beeps) another card has already 
been input (duplicate card). 
B. 
Red
 light comes on:
 This slot already has a code registered 
1. Press「**」(deletion) Æ Green light Æ Enter the slot position code again 
Æ
Present the card in front of the reader Æ﹝same as Step “A”﹞  
2. 
Enter another slot card position 
 
‹
  Add PIN codes and deletion  
       
Enter the Programming mode, Enter the slot position code 「101~150」
 
A. 
Green
 light comes on:
 This slot position code may register the PIN codes 
Input 5 digit PIN codes ÆYellow LED blinks (beep) Æ enrolled Æ(repeat) 
B. 
Red
 light comes on:
 This slot position code is registered 
1. Press「**」(deletion) Æ Green light Æ Press the slot position code again Æ 
Input 5 digit PIN codes Æ﹝same as Step “A”﹞ 
2.  Enter another slot card position 
Note 1:
 The codes"12345" or master code are not be used for PIN code. 
Note 2:
 PIN codes operate open door:「???????????*****#」 
???….」random codes,「*****」5 digit PIN codes,「#」Enter
 
 
‹
  To Program Relocking Timer 
        
Enter the Programming mode, 
A. Relay 
1:Press「*10」Followed by the number of seconds the relay should 
open→「05」=5 seconds(01 ~99 = seconds)→(beep)→enrolled → Press 
#」 to exit from the programming mode, or program other operating. 
B. Enter「00」Sets the relay to latching mode.
 
(Correct code entered opens the relay, 
and the relay stays open until the correct code is entered again). 
C. Relay 
2:Press「*20」Followed by the number of seconds the relay should 
open)→「05 =5 seconds (01 ~99 = seconds).  →(beep)→enrolled → Press 
#」 to exit from the programming mode, or program other operating. 
D. Enter「00」Sets the relay to latching mode.
 
(Correct code entered opens the relay, 
and the relay stays open until the correct code is entered again). 
 
‹
  Changing the Master codes: 
        
Enter the Programming mode, Enter「*00」Followed by the new 5 digit master 
code→(beep)→enrolled→Enter 「#」 to exit from the programming mode, or 
program other operating.