Output Function Adjustment Parameters
The following parameters work in 
conjunction with the intelligent output 
function, when configured. The overload 
level parameter (C_41) sets the motor 
current level at which the overload signal 
[OL] turns ON. The range of settings is 
from 0% to 200% of the rated current for 
the inverter. This function is for generating 
an early warning logic output, without 
causing either a trip event or a restriction 
of the motor current (those effects are 
available on other functions).
The frequency arrival signal, [FA1] or 
[FA2], is intended to indicate when the 
inverter output has reached (arrived at) the 
target frequency. You can adjust the timing 
of the leading and trailing edges of the 
signal via two parameters specific to accel-
eration and deceleration ramps, C_42 and 
C_43.
The Error for the PID loop is the magni-
tude (absolute value) of the difference 
between the Setpoint (desired value) and 
Process Variable (actual value). The PID 
output deviation signal [OD] (output 
terminal function option code 04) 
indicates when the error magnitude has 
exceeded a magnitude you define.
Motor current
Overload 
signal
C 41
t
t
0
1
0
Output
frequency
Arrival 
signal
C 43
C 42
t
t
0
1
0
PID Error (PV–SP) deviation threshold
Devia-
tion sig-
C 44
t
t
SP
Output
PV
0
1
0
“C” Function
Run 
Mode 
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE 
(CE)
–FU 
(UL)
–FR 
(Jpn)
Units
C_41 Overload level setting
Sets the overload signal level 
between 0% and 200% (from 0 
to two times the rated current 
of the inverter)
Rated current for each 
inverter
OV Load   03.00A
C_42 Frequency arrival 
setting for acceleration
Sets the frequency arrival 
setting threshold for the output 
frequency during acceleration
0.0
0.0
0.0
Hz
ARV ACC  000.0Hz