Spare parts
We recommend that you stock spare parts to reduce down time, including these parts:
Capacitor Life Curve
The DC bus inside the inverter uses a large capacitor as shown in the diagram below. 
The capacitor handles high voltage and current as it smooths the power for use by the 
inverter. So, any degradation of the capacitor will affect the performance of the inverter.
Capacitor life is reduced in higher ambient temperatures, as the graph below demon-
strates. Be sure to keep the ambient temperature at acceptable levels, and perform 
maintenance inspections on the fan, heat sink, and other components. If the inverter is 
installed on a cabinet, the ambient temperature is the temperature inside the cabinet.
Part description
Symbol
Quantity
Notes
Used
Spare
Cooling fan
FAN
1
1
022NF, 037LF, 015HF to 
075HF
Case
CV
1
1
Front case
Key cover
Case
Bottom cover
Power 
Input
Inverter
L1
Motor
L2
L3
Rectifier
Variable-frequency Drive
Internal
DC Bus
+
+
U/T1
V/T2
W/T3
Con-
Capacitor
1
2
3
4
5
6
7
8
9
10
0
10
20
30
40
-10
Ambient temperature, °C
Years
Capacitor Life Curve
Operation for 12 hours/day