Trip Event and History Monitoring
The trip event and history monitoring feature lets you cycle through related information 
using the keypad. See 
 for 
more details.
D_07 Scaled output frequency 
monitor
Displays the output frequency 
scaled by the constant in B_86. 
Decimal point indicates range:
XX.XX   0.01 to 99.99
XXX.X   100.0 to 999.9
XXXX.   1000 to 9999
XXXX     10000 to 99990
Hz
/Hz01.0     0.00
“D” Function
Run 
Mode 
Edit
Range 
and 
Units
Func.
Code
Name /
SRW Display
Description
“D” Function
Run 
Mode 
Edit
Range 
and 
Units
Func.
Code
Name /
SRW Display
Description
D_08 Trip event monitor
Displays the current trip event. 
information.
ERR1      EEPROM
ERR1       0.0Hz
ERR1        0.0A
ERR1    324.3Vdc
ERR1 RUN 000000H
D_09 Trip history monitor
Displays the previous two 
events and their causes.
ERR2      EEPROM
ERR2       0.0Hz
ERR2        0.0A
ERR2    330.0Vdc
ERR2 RUN 000000H
ERR3      EEPROM
ERR3       0.0Hz
ERR3        0.0A
ERR3    328.7Vdc
ERR3 RUN 000000H
Cumulative operation 
RUN time monitor
Displays total time the inverter 
has been in RUN mode in 
hours.
hours
RUN      000000H
Trip count
Displays cumulative number of 
trip events.
trips
ERROR COUNT  009