Hitachi L100 사용자 설명서

다운로드
페이지 192
L100 Inverter
Conf
igur
ing
Dr
iv
e P
a
ra
m
e
ters
3–21
Accel/Decel
Standard acceleration and deceleration is 
linear. The inverter CPU can also calculate 
an S-curve acceleration or deceleration 
curve as shown. This profile is useful for 
favoring the load characteristics in particu-
lar applications.
Curve settings for acceleration and decel-
eration are independently selected. To 
enable the S-curve, use function A_97 
(acceleration) and A_98 (deceleration).
Acceleration period
S-curve
Linear
Accel. curve selection
Target 
freq.
Output
frequency
t
0
A_97 = 00
A_97 = 01
“A” Function
Run 
Mode 
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE 
(CE)
–FU 
(UL)
–FR 
(Jpn)
Units
A_97 Acceleration curve 
selection
Set the characteristic curve of 
Acc1 and Acc2, two options:
00 ...linear
01 ...S-curve
00
00
00
ACCEL LINE     L
A_98 Deceleration curve 
selection
Set the characteristic curve of 
Acc1 and Acc2, two options:
00 ...linear
01 ...S-curve
00
00
00
DEC LINE       L