Runco sp-50dhd 사용자 설명서

다운로드
페이지 82
46
PlasmaWall SP Series Owner’s Operating Manual
PRE
L
IMINAR
Y
Analog Out Mode: Select Analog Out Mode from the Service menu to change the 
characteristics of the analog output signal from the DHD Controller. The choices are 
RGB-- (separate sync with negative polarity), RGB++ (separate sync with positive polarity) 
or RGBS (composite sync).
Display Device: The options in the Display Device menu allow you to perform certain 
adjustments at the plasma display.
• Input Source: Select Input Source from the Display Device menu to switch from one 
DHD Controller output/PlasmaWall input to the other. Use the 
 or 
 button to select 
RGB or DVI/HDMI, then press ENTER
 
• Configure: Select Configure from the Display Device menu to perform the following 
display device adjustments (these are global, independent of any input):
• Select Left/Right or Up/Down and use the 
 or 
 buttons to fine-tune the 
displayed image position.
• Select Width or Height and use the 
 or 
 buttons to fine-tune the display device 
aspect ratio.
HD Format: If the characteristics of the incoming signal on the HD1 or HD2 inputs are 
known, select HD Format from the Service menu and set them as described below. Doing 
so can reduce the time it takes the DHD Controller to switch from HD to 480i signals or 
vice versa. 
This is generally not necessary unless the DHD Controller – for whatever reason – has 
difficulty determining the color space (RGB or YUV), bandwidth or resolution of the 
incoming HD signal. In most situations, the Auto settings work well. 
• HD/RGB 1 and HD/RGB 2 (Color Space): Select Auto, RGB or YUV.
• ADC Bandwidth: Select Auto, 75 MHz, 150 MHz or 300 MHz.
• YPbPr Input Resolution: Select Auto or specify the input resolution, if known: 480i, 
480p, 576i, 576p, 720p or 1080i. 
Triggers: Select Triggers from the Service menu to configure the 12-volt trigger outputs. 
You can assign one or more trigger outputs to each aspect ratio. Those triggers are then 
activated by selecting that aspect ratio. 
To save the trigger settings so that they can be restored after a System Reset (described 
below), press 
 repeatedly to highlight “Save.” Then, press ENTER
If the DVI 1 or DVI 2 DHD Controller input is active and the input signal is 
HDCP-encrypted, the RGBHV output of the DHD Controller is disabled.
Use the serial command DISPLAY 1 or DISPLAY 2 to set the Input 
Source to RGB or DVI/HDMI respectively, so that the DHD Controller 
retains this setting after a System Reset
. (This is not the case when you 
change the Input Source in the Display Device menu.) For more 
information, refer to Miscellaneous Commands
 on page 57. 
 
Note
Tip