Regarding the indicator lamps 
Lighting and flashing of the POWER indicator, the LAMP indicator, and the 
TEMP indicator have the meanings as described in the table below. Please respond 
in accordance with the instructions within the table. If the same indication is 
displayed after the treatment, or if an indication other than the following is 
displayed, please contact your dealer or service company. 
POWER 
indicator 
LAMP 
indicator 
TEMP 
indicator
Description 
Lighting 
in 
Orange
 
Turned 
off 
Turned
off 
The projector is in a standby state. 
Please refer to the section “Power On/Off”. (
16) 
Blinking 
in 
Green
 
Turned 
off 
Turned
off 
The projector is warming up. 
Please wait. 
Lighting 
in 
Green
 
Turned 
off 
Turned
off 
The projector is in an on state. 
Ordinary operations may be performed. 
Blinking 
in 
Orange
 
Turned 
off 
Turned
off 
The projector is cooling down. 
Please wait. 
Blinking 
in 
Red
 
(discre- 
tionary) 
(discre-
tionary)
The projector is cooling down. A certain error 
has been detected. 
Please wait until the POWER indicator finishes 
blink, and then perform the proper response 
measure using the item descriptions below as 
reference. 
Blinking 
in 
Red
 
or 
Lighting 
in 
Red
 
Lighting 
in 
Red
 
Turned
off 
The lamp does not light, and there is a possibility 
that interior portion has become heated. 
Please turn the power off, and allow the unit to cool 
down at least 20 minutes. After the projector has 
sufficiently cooled down, please make confirmation of 
the following items, and then turn the power on again. 
Is there blockage of the air passage aperture? 
Is the air filter dirty? 
Does the peripheral temperature exceed 35°C? 
If the same indication is displayed after the 
treatment, please change the lamp by referring to 
the section “Lamp”. (
41) 
Blinking 
in 
Red
 
or 
Lighting 
in 
Red
 
Blinking 
in 
Red
 
Turned
off 
The lamp cover has not been properly fixed 
(attached). 
Please turn the power off, and allow the unit to cool 
down at least 45 minutes. After the projector has 
sufficiently cooled down, please make confirmation of 
the attachment state of the lamp cover. After performing 
any needed maintenance, turn the power on again. If the 
same indication is displayed after the treatment, please 
contact your dealer or service company.