Hoshizaki FD-1001MAH(-C) 사용자 설명서

다운로드
페이지 103
5
1-in-1 drain cycle. DV opens for 
 seconds every hour 
(S1
 Dip Switch 4).
Icemaker status does not change.
FD Sequence Flow Chart
LF/S
 closed
UF/S
 closed
FT 
off
WV
 off
3. 1-in-12 Drain Cycle 
& Restart (optional)
3.
 Icemaker Off
UF/S
 open 
LF/S
 open (WV on)
FT
 started (90 sec.)
WV
 on
CR 
continues
Comp
 continues
GMR 
continues
GM
 continues
GMPR
 continues
FM 
continues
FMR
 co
ntinues
LLV
 continues
SLV 
continues
1. Startup
2. Ice Purge Cycle
WV
 on
FT
 on (90 sec.)
CR 
on
Comp
 on
LLV 
on
SLV
 on
GMR
 continues
GM 
continues
GMPR
 continues
FM
 continues
FMR
 continues
Power Switch "ON" 
Control Switch in "ICE"
POWER OK LED on
IS Green LED on
IS Yellow LED off
2. Infrared Sensor Shutdown & Restart
1. Bin Full
IS 
activated or 
DC
 starts
CR 
off
Comp
 off
LLV
 off
SLV 
off
GMR 
continues
GM
 continues
GMPR
 continues
FM 
continues
FMR 
continues
1. Fill Cycle
3. Freeze Cycle
LF/S
 closed
UF/S
 closed
FT
 off
WV
 off
CR
 co
ntinues
Comp
 continues
GMR 
continues
GM
 continues
GMPR
 continues 
FM 
continues
FMR 
continues
 
LLV 
continues
SLV 
continues
Low Water Safety 
UF/S 
open
WV
 on 
FT 
exceeded
1-beep
 alarm 
sounds
CR 
off
Comp
 off
LLV 
off
SLV 
off
GMR 
continues
GM 
continues
GMPR
 continues
FM 
continues
FMR 
continues
DV 
on (
DC
 only)
GMR 
off
GM
 off
GMPR
 off
FM 
off
FMR 
off
2.
 Ice Purge Cycle
10-min. DT 
off (
DC
 only)
DV 
off (
DC
 only)
1-in-12 DT 
reset (
DC
 only)
IS Green LED on
IS Yellow
 LED (flashing or steady)
IS delay determined by S1 dip switch 
1, 
, & 3 
4. Icemaker Restart
5 minutes 
Note: If IS fails to shutdown the 
icemaker, MBC opens and a 
9-beep alarm sounds.
4. Icemaker Restart 
 
2.
 Ice Purge Cycle
3.
 10-Minute 
 
    Drain
 
Legend:
Comp
-compressor
CR
-compressor relay
DC
-drain cycle
DT
-drain timer
DV
-drain valve
FM
-fan motor
FMR
-fan motor-remote
FT
-fill timer (low water safety)
GM
-gear motor
GMPR
-gear motor protect relay
GMR
-gear motor relay (X
 CB)
IS
-infrared sensor bin control
LF/S
-lower float switch
LLV
-liquid line valve (MLH only)
MBC
-mechanical bin control
PT
-purge timer
SLV
-suction line valve (MLH only)
UF/S
-upper float switch
WV
-water valve
If Fil
l > 90 sec. 
FT
 
1-beep alarm
 sounds
WV
 continues
When UF/S closes 
alarm resets and 
. Ice Purge Cycle starts.
Maximum
90
 seconds
4. 1-in-12 Drain Cycle - 
Although the 
factory default 1-in-1 drain cycle 
is recommended, a 1-in-1
 drain cycle is available. For 1-in-1
 drain 
cycle sequence, see "3. 1-in-1
 Hour Drain Cycle & Restart (optional)." 
Refill 
 
FT Maximum
90
 seconds
90 sec. 
FT
 exceeded
1-beep alarm
 sounds
90 sec. 
PT
 begins
When UF/S closes, 
alarm resets and 
.
 Ice Purge Cycle 
starts.
1-beep alarm
 continues 
WV 
continues
GMR 
off
GM 
off
GMPR
 off
FM 
off
FMR 
off
IS Green LED on
IS Yellow LED off
IS Green LED on
IS Yellow LED off
1.
 DT Initiates DC
To bypass, press the 
"SERVICE" button after 
GM starts.
5 minutes 
to "
. Ice Purge Cycle" above
to "1. Fill Cycle" above
90
 seconds
(S1 dip switch 4)
FT
 off (90 sec.)
FT
 exceeded
PT
 terminates
30 sec. 
 
GMR
 on
GM
 on
GMPR
 on
FM 
on
FMR 
on
2. Sequence Flow Chart