e) Bin Control Selector (S1 dip switch 7)
This unit is factory set for infrared sensor bin control operation. No adjustment is 
required. When used on a standard ice storage bin, the mechanical bin control may be 
used instead of the infrared sensor by moving S1 dip switch 7 to the off position. In the 
factory default position (S1 dip switch 7 in the on position), the gear motor delay after the 
upper float switch closes is 30 seconds. When the mechanical bin control is used (S1 dip 
switch 7 in the off position), the gear motor delay after the upper float switch closes is 
5 seconds. 
WARNING! Do not place S1 dip switch 7 in the off position on dispenser 
unit applications.
S1 Dip Switch 
Setting
Bin Control Application
Gear Motor Delay
No. 7
OFF
Mechanical Bin Control (Standard Ice Storage Bins Only)
5 seconds
ON
Infrared Sensor with
Mechanical Bin Control Backup
30 seconds
f) Mechanical Bin Control Shutdown Delay (S1 dip switch 8)
Factory set for normal operation. No adjustment is required. The shutdown delay is the 
time between the mechanical bin control proximity switch opening and the control board 
shutting off the icemaker. 
S1 Dip Switch 
Setting
Bin Control #1 
Shutdown Delay
No. 8
OFF
0.5 Seconds
ON
6.7 Seconds
g) Factory Use (S1 Dip Switch 9 & 10)
Factory set for optimum performance. Do not adjust.