 Shutdown – See "IV.D. Bin Control Check."
Legend: 
CB–control board; Comp–compressor; DV–drain valve; EHH–extruding 
head heater (-C model only); 
FM–fan motor; FMR–fan motor-remote;     
GM–gear motor; GMPR–gear motor protect relay; GMR–gear motor 
relay; 
IS–infrared sensor; LF/S–lower float switch; LLV–liquid line 
valve (MLH model only); 
MBC–mechanical bin control; SLV–suction line 
valve (MLH model only); 
UF/S–upper float switch; WV–inlet water valve 
C. Control Board Check
Before replacing a control board that does not show a visible defect and that you suspect 
is bad, always conduct the following check procedure. This procedure will help you verify 
your diagnosis. 
1) Check the S1 dip switch settings to assure that they are in the factory default position. 
S1 dip switch 7 is determined by bin control application:
Bin Control Application: 
Infrared Sensor Bin Control:
 S1 dip switch 7 in the "OFF" position.
Mechanical Bin Control: S1 dip switch 7 in the "ON" position. 
For factory default settings, see "II.C.4.a) Default Dip Switch Settings."
) Move the power switch to the "ON" position and move the control switch to the "ICE" 
position. The "POWER OK" LED turns on. 
Diagnosis "POWER OK" LED: Check that 
the "POWER OK" LED is on. If not, check for proper supply voltage (115VAC) input to 
the control transformer (power switch, breaker, fuse, and circuit protect relay). Next, 
check for proper low-voltage (4VAC) output from the control transformer and that 
the 1A fuse is good. Check for 4VAC from K8 connector pin #1 white/red (W/R) to 
K8 connector pin # light blue (LBU). If 4VAC is present and the "POWER OK" LED is 
off, the control board is bad and must be replaced. 
3) "WTRIN" LED is on: When the lower or upper float switch is open, the inlet water valve 
energizes and water fills the reservoir. 
Diagnosis: If "WTRIN" LED is off, upper float 
switch is closed (reservoir full), "GM" LED is on, and the gear motor energizes, skip 
to step 8. If "WTRIN" and "GM" LED are off, confirm that the control switch is in the 
"ICE" position (open). Check that the yellow LED on the infrared sensor is not steady 
or flashing (see step 4 below). Next, check the continuity of the lower and upper float 
switches (open or closed). For further details, see 5.f. below. If the lower or upper 
float switch is open and the "WTRIN" LED is off, the control board is bad and must be 
replaced. If the "WTRIN" LED is on and the lower or upper float switch is open, water 
should be filling the reservoir. If not, skip to step 6.