MECHANICAL COMPONENTS
Bellows condensate valve  Temperature-sensitive valve 
that opens up to drain off condensate water when the outside 
temperature falls below 40°F and closes when the outside 
temperature reaches 58°F.
Vent door  Allows introduction of fresh air into the room 
and/or exhausts stale room air outside (on select models.)
Plenum assembly  Diffuser with directional louvers used 
to direct the conditioned airfl ow.
Blower wheel  Attaches to the indoor side of the fan motor 
shaft and is used for distributing unconditioned, room side 
air though the heat exchanger and delivering conditioned 
air into the room.
Slinger fan blade  Attaches to the outdoor side of the fan 
motor shaft and is used to move outside air through the 
condenser coil, while slinging condensate water out of the 
base pan and onto the condenser coil, thus lowering the 
temperature and pressures within the coil.
ELECTRICAL COMPONENTS
Thermostat  Used to maintain the specifi ed room side 
comfort level
System switch  Used to regulate the operation of the fan 
motor, the compressor or to turn the unit off. For troubleshoot-
ing, refer to the wiring diagrams and schematics in the back 
of this service manual.
Capacitor  Reduces line current and steadies the voltage 
supply, while greatly improving the torque characteristics of 
the fan motor and compressor motor.
ELECTRONIC CONTROLS
TESTING THE ELECTRONIC CONTROLS
CHECK FILTER light will come on after 250 hours of use. 
Touch CHECK FILTER to reset.
Electronic Control
Check
Filter
Press to reset
Set Hour
Clock
On/Off
Cool
Cooler
Money
Saver
Fan
Only
Warmer
0
F/
0
C
Speed
1-4
Smart
Fan
A/C
Stop
A/C
Start
Timer
On/Off
PM
72
ELECTRICAL COMPONENTS cont’d
MoneySaver
®
 switch  When engaged, it sends the power 
supply to the fan motor through the thermostat, which allows 
for a cycle-fan operation.
Fan Motor  Dual-shafted fan motor operates the indoor 
blower wheel and the condenser fan blade simultaneously.
Solenoid  Used to energize the reversing valve on all heat 
pump units.
Heating element  Electric resistance heater, available in 3.3, 
4.0 or 5.2 kW on select TwinTemp
®
 models.
Heat anticipator  Used to provide better thermostat and 
room air temperature control.
HERMETIC COMPONENTS
Compressor  Motorized device used to compress refrigerant 
through the sealed system.
Reversing valve  A four-way switching device used on all 
heat pump models to change the fl ow of refrigerant to permit 
heating or cooling.
Check valve  A pressure-operated device used to direct the 
fl ow of refrigerant to the proper capillary tube, during either 
the heating or cooling cycle.
Capillary tube  A cylindrical meter device used to evenly dis-
tribute the fl ow of refrigerant to the heat exchangers (coils.)
FUNCTIONAL COMPONENT DEFINITIONS