PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting
line tubing.
2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data
Table.
4. For TXV match charge weight needs to be weighed in for specific coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator
+ adder for line set.
System Charge for Various Matched Systems
Outdoor Unit
TCGF24S41S1
TCGF30S41S1
TCGF36S41S1
TCGF42S41S1
TCGF48S41S1
TCGF60S41S1
Required Orifice or TXV
1
1TVM4F1
1TVM4G1
1TVM4G1
1TVM4G1
1TVM4J1
1TVM4J1
Factory Charge, lbs-oz
3 - 2
3 - 7
3 - 10
4 - 4
4 - 9
5 - 9
Indoor Coil
2,3,4
Additional Charge, oz
FC/MC/PC24
10
–
–
–
–
–
FC/MC/PC30
10
2
–
–
–
–
FC/MC/PC35
16
10
–
–
–
–
FC/MC/PC36
10
4
5
–
–
–
FC/MC/PC37
24
19
15
–
–
–
FC/MC/PC43
24
19
15
5
–
–
FC/MC/PC48
40
32
27
17
16
–
FC/MC/PC60
–
–
–
17
16
0
FC/MC62
–
–
–
25
26
18
FC64
–
–
–
30
33
25
UC24
8
–
–
–
–
–
UC60
–
–
12
–
–
–
HC30
10
–
–
–
–
–
HC36
16
11
8
–
–
–
HC42
25
19
15
6
–
–
HC60
–
–
–
0
0
0
HD24
16
–
–
–
–
–
HD36
18
–
–
–
–
–
HD48
51
42
36
24
25
–
HD60
–
–
–
–
24
24
AHP30
16
–
–
–
–
AHP36
–
19
15
–
–
–
AHX30
16
11
–
–
–
–
AHX36
–
11
15
–
–
–
AHX42
–
31
27
17
–
–
AHX48
–
31
27
17
16
–
AHX60
–
–
33
22
23
18
AHP/SHP60
–
–
–
–
1
–
AV*24
3
–
–
–
–
–
AV*36
25
19
15
–
–
–
AV/SV*48
–
–
9
0
1
–
AV/SV*60
–
–
–
0
1
0
F4FP030
3
–
–
–
–
–
F4FP036
–
–
5
–
–
–
F4FP040
–
–
8
–
–
–
F4FP042
–
–
8
–
–
–
F4FP045
–
–
9
–
–
–
F5FP048
–
–
20
10
11
–
F5FP060
–
–
20
10
11
–
F4FV060
–
–
9
10
1
–
F6FP030
17
11
–
–
–
–
F6FP036
–
11
8
–
–
–
F6FP042
–
23
19
17
–
–
F6FP048
–
23
19
17
16
–
F6FP060
–
–
33
23
23
18
FOOTNOTES:
1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
2. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
3. A TXV kit must be used with these coils to obtain system performance. Note: If a TXV is factory installed on the coil, it must be replaced with
2. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
3. A TXV kit must be used with these coils to obtain system performance. Note: If a TXV is factory installed on the coil, it must be replaced with
the listed TXV.
4. Refer to Technical Guide for actual system performance for specified matches.