National Instruments 800 Series 사용자 설명서

다운로드
페이지 104
Chapter 3
VXIpc 800 Series Configuration and Installation
VXIpc 800 Series User Manual
3-10
© National Instruments Corporation
If this situation occurs after you change the configuration, perform the 
following steps to reconfigure the VXIpc-800.
1.
Turn your computer off.
Warning: To protect both yourself and the mainframe from electrical hazards, the 
mainframe should remain off until you are finished changing the settings 
on the VXIpc-800 module.
2.
Change switch S9 to the OFF position as shown in Figure 3-9b to 
restore the factory configuration.
3.
Turn on the computer. The computer should boot this time because 
the factory-default configuration is being used to initialize the 
VXIpc-800 module.
4.
Run your software configuration utility to re-adjust the VXIpc-800 
configuration.
5.
After saving the configuration, exit Windows and turn off the 
computer.
6.
Change switch S9 to the ON position, as shown in Figure 3-9a.
7.
Turn on the computer. If the computer does not boot with this 
configuration, you will have to repeat these steps, modifying your 
configuration until a final configuration is reached.
Installed System RAM
The 16 MB of installed RAM is factory configured per customer order. 
You can change the amount of installed RAM on the VXIpc 800 Series 
by installing DRAM SIMMs. Refer to Appendix ASpecifications, for 
more information on SIMMs.
Configuring the PC
This section describes how to configure the following options on 
the PC:
SCSI termination
GPIB interrupt level
System CMOS
Parallel port DMA level
Ethernet power-on defaults