TRoUBlesHooTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Switch in OFF position (mod-
ule gives long steady beep)
2. Bad  batteries  (If  batteries 
fail within 1 heating season, 
see cause no. 8)
3. Ignitor  electrode  not  con-
nected to ignitor cable
4. Ignitor  cable  pinched  or 
wet
5. Broken ignitor cable
6. Bad piezo ignitor
7. Ignitor electrode positioned 
wrong or broken
8. Bad module
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Bad  batteries  (If  batteries 
fail within 1 heating season, 
see cause no. 9)
3. Control knob not in PILOT 
position
4. Control knob not pressed in 
while in PILOT position
5. Air  in  gas  lines  when  in-
stalled
6. Depleted  gas  supply  (pro-
pane/LP only)
7. ODS/pilot is clogged
8. Gas regulator setting is not 
correct
9. Bad module
1. Inlet  gas  pressure  is  too 
low
2. Wire disconnected from gas 
control
3. Burner orifice(s) clogged
4. Bad module
OBSERVED PROBLEM
When 
  and 
  are 
pressed  at  the  same  time, 
there  is  no  spark  at  ODS/
pilot
When 
  and 
  are 
pressed,  there  is  spark  at 
ODS/pilot but no ignition
Burner  does  not  light  after 
pilot is lit
REMEDY
1. Push switch on valve to "–" 
position
2. Replace batteries
3. Reconnect ignitor cable
4. Free ignitor cable if pinched 
by  any  metal  or  tubing. 
Keep ignitor cable dry
5. Replace ignitor cable
6. Replace piezo ignitor
7. Replace pilot assembly
8. Replace module
1. Turn on gas supply or open 
equipment shutoff valve
2. Replace batteries
3. Turn control knob to PILOT 
position
4. Press in control knob while 
in PILOT position
5. Continue  holding  down 
control knob. Repeat ignit-
ing  operation  until  air  is 
removed
6. Contact  local  propane/LP 
gas company
7. Clean ODS/pilot (see Clean-
ing and Maintenance, page 
20)  or  replace  ODS/pilot 
assembly
8. Replace gas regulator
9. Replace module
1. Contact  local  natural  or 
propane/LP gas company
2. Reconnect leads (see Wir-
ing Diagram, page 24)
3. Clean burner (see Cleaning 
and Maintenance, page 20) 
or replace burner orifice(s)
4. Replace module