 WARNING: Never install the 
heater
•  in a bedroom or bathroom 
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing  or  other  flammable 
objects are less than 36" from 
the front, and 42" from top of 
heater. For side clearances see 
Figure 4, page 9
•  in high traffic areas
•  in windy or drafty areas
 CAUTION: This heater cre-
ates  warm  air  currents.  These 
currents move heat to wall sur-
faces  next  to  heater.  Installing 
heater next to vinyl or cloth wall 
coverings  or  operating  heater 
where impurities (such as, but 
not limited to, tobacco smoke, 
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in 
the air exist, may discolor walls 
or cause odors.
  WARNING:  Antenna  and 
ignition cable must maintain a 
spacing of 3/4". Failure to keep 
them  separated  will  result  in 
damage to the receiver. See Wir-
ing Diagram on page 24.
IMPORTANT: Vent-free heaters add moisture 
to the air. Although this is beneficial, installing 
heater  in  rooms  without  enough  ventilation 
air may cause mildew to form from too much 
moisture. See Air for Combustion and Ventila-
tion
, page 5.
CHECK GAS TYPE
Use the correct gas type (natural or propane/
LP) for your unit. If your gas supply is not cor-
rect, do not install heater. Call dealer where 
you bought heater for proper type heater.
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
 WARNING: Before installing 
in a solid fuel burning fireplace, 
the  chimney  flue  and  firebox 
must be cleaned of soot, creo-
sote, ashes and loose paint by 
a  qualified  chimney  cleaner. 
Creosote  will  ignite  if  highly 
heated. A dirty chimney flue may 
create and distribute soot within 
the house. Inspect chimney and 
firebox flue for damage. If dam-
aged,  repair  flue  and  firebox 
before operating heater.
  WARNING:  Seal  any  fresh 
air vents or ash clean-out doors 
located on floor or wall of fire-
place. If not, drafting may cause 
pilot  outage  or  sooting.  Use  a 
heat-resistant  sealant.  Do  not 
seal chimney flue damper.